Secondary Containment Basins
Cast-in-place containment basins engineered for environmental compliance and spill protection.
View service
Industrial & Infrastructure
Chemical-resistant containment pads and tank foundations built for manufacturing and utility clients.
We plan, engineer, and execute containment & tank pads across North Texas industrial, commercial, and municipal job sites. Our team coordinates design, logistics, and QA so every placement supports the overall critical path of your project.
Explore connected scopes or search the catalog.
Cast-in-place containment basins engineered for environmental compliance and spill protection.
View servicePrecision machine bases and vibration-isolated foundations tailored to manufacturing equipment tolerances.
View serviceEngineered retaining and MSE wall solutions that manage grade changes around municipal and commercial sites.
View serviceHeadwalls, flumes, inlets, and box culverts cast to manage commercial stormwater requirements.
View serviceNear-site markets with crews staged for rapid deployment.
Sherman
Grayson County, TX
Headquarters for our North Texas operations with crews staged for municipal, industrial, and campus concrete programs.
Denison
Grayson County, TX
Commercial and civic concrete services supporting the US-75 corridor, rail-served industry, and local capital programs.
Howe
Grayson County, TX
Concrete packages for rail-served parks, manufacturing additions, and TxDOT-connected infrastructure.
Pottsboro
Grayson County, TX
Lake Texoma commercial projects, marina infrastructure, and municipal improvements delivered with minimal downtime.
Bells
Grayson County, TX
Civil and vertical concrete scopes supporting schools, municipal work, and US-82 corridor projects.
Van Alstyne
Grayson County, TX
Support for commercial growth along US-75 including logistics pads, shell buildings, and site paving.
Savoy
Fannin County, TX
Concrete repair, containment pads, and small capital projects for local industry and utilities.
Collinsville
Grayson County, TX
Municipal, school, and commercial pours with rapid mobilization along SH-377.
We install several types of containment pads for chemical storage tanks in Sherman, TX industrial facilities, including chemical-resistant concrete pads, secondary containment systems, and integrated tank foundation and containment solutions. Chemical-resistant containment pads utilize specialized concrete formulations incorporating chemical-resistant additives, appropriate aggregates, and protective systems where required to withstand chemical exposure from stored materials. Pad design incorporates appropriate thickness requirements typically ranging from 6 to 12 inches, depending on tank loading, soil conditions, and operational demands. Reinforcement strategies include welded wire fabric or rebar grids providing structural capacity and crack control. Secondary containment provisions address spill protection and environmental compliance, including containment volume calculations and impermeability requirements. Integrated systems combine tank foundation support with containment functionality, providing structural support while ensuring environmental protection. Design considerations address chemical compatibility with stored materials, exposure conditions, and long-term performance under chemical exposure. Construction execution requires careful material selection, proper placement techniques, and quality control ensuring chemical resistance and environmental protection. The resulting containment pads in Sherman, TX industrial facilities support chemical storage tanks while providing effective environmental protection and regulatory compliance.
Designing tank foundations to meet environmental compliance requirements in Denison, TX requires comprehensive understanding of federal, state, and local regulations addressing storage of hazardous materials, spill prevention, and environmental protection. Our design process begins with regulatory analysis evaluating EPA regulations, Texas Commission on Environmental Quality requirements, and local code provisions applicable to specific storage applications. Foundation design incorporates secondary containment provisions addressing spill protection and environmental compliance, including containment volume calculations ensuring adequate capacity for potential spills. Impermeability requirements prevent leakage that could cause environmental contamination, requiring careful attention to concrete formulation, joint construction, and surface protection. Design considerations address capacity requirements, drainage management, and emergency response provisions ensuring effective spill containment. Structural design ensures adequate capacity to support tank loads while maintaining integrity under operational conditions. Integration with monitoring systems may be required to detect leaks or spills promptly. Construction specifications address material selection, placement techniques, and quality control ensuring compliance with regulations. Documentation and reporting requirements ensure that foundations meet applicable regulations and provide adequate environmental protection. The resulting tank foundation designs in Denison, TX meet environmental compliance requirements while providing reliable structural support and effective environmental protection.
Concrete specifications for chemical-resistant containment pads in McKinney, TX manufacturing facilities require specialized formulations addressing chemical resistance, structural capacity, and environmental protection. Chemical-resistant concrete typically incorporates specialized additives enhancing resistance to acids, bases, solvents, and hydrocarbons depending on stored materials and operational conditions. Concrete strength specifications typically require minimum 3000 to 4000 psi compressive strength, with higher strengths specified for particularly demanding applications. Chemical-resistant aggregates may be specified to enhance resistance to specific chemical exposures. Air entrainment requirements address freeze-thaw durability important for North Texas conditions. Slump specifications ensure proper placement and consolidation while maintaining workability. Reinforcement strategies typically include welded wire fabric or rebar grids providing structural capacity and crack control under demanding conditions. Thickness requirements typically range from 6 to 12 inches, depending on tank loading, soil conditions, and operational demands. Surface finish requirements create appropriate texture while maintaining chemical resistance. Joint construction requires careful attention to ensure impermeability and chemical resistance. Protective coatings or sealers may be specified to enhance chemical resistance and protect against degradation. Quality control measures include concrete testing, material verification, and inspection programs ensuring compliance with specifications. These concrete specifications ensure that McKinney, TX manufacturing facility containment pads withstand chemical exposure while maintaining structural integrity and environmental protection throughout extended service life.
Yes, we provide comprehensive containment pad and tank foundation services for industrial and utility facilities throughout the Dallas-Fort Worth metroplex. Our capabilities encompass chemical-resistant containment pads, tank foundation systems, and integrated solutions supporting equipment while providing environmental protection and regulatory compliance. We serve chemical storage facilities, manufacturing plants, water treatment facilities, wastewater treatment plants, and utility installations requiring specialized containment systems. Our engineering expertise addresses tank loading, chemical resistance requirements, secondary containment provisions, and environmental compliance. Construction capabilities include site preparation, concrete placement, reinforcement installation, and secondary containment construction. We utilize chemical-resistant concrete formulations and appropriate construction techniques ensuring chemical resistance and environmental protection. Quality control measures include comprehensive testing and inspection programs verifying structural capacity, chemical resistance, and compliance with specifications. We coordinate effectively with facility operators, environmental consultants, and regulatory agencies to ensure compliance with applicable regulations. Our experience with DFW industrial and utility facilities includes understanding operational requirements, accommodating phasing needs, and delivering containment systems that support operations while ensuring environmental protection. We serve clients throughout the metroplex, providing containment pad and tank foundation solutions that meet demanding requirements and support long-term operational success for industrial and utility facilities in Dallas-Fort Worth, TX.
Share your drawings, soils data, and schedule details. Our engineering and field leaders will prepare a concrete delivery plan tailored to your site.